900,000.00950,000.00 (-5%)

In stock

  • Power range 4KW-12KW
  • 24/48VDC input voltage
  • Powerful charge rate up to 100Amp
  • Inbuilt pure copper transformer
  • Pure sine wave output
  • LED+LCD display
  • MPPT solar charge controller 60A/120A option
  • MPPT efficency max 98%
  • 50/60HZ automatic sensing
  • RS232 with free CD
  • Battery priority function
  • Automatically send signal to start generator
  • DC start&automatic self-diagnostic function
  • High efficiency design&"power saving mode"to conserve energy
  • MODEL PV35-5KW PV35-6KW PV35-8KW PV35-10KW PV35-12KW
    Default Battery System Voltage 24VDC 48VDC 24VDC 48VDC 24VDC 48VDC 48VDC 48VDC
    INVERTER
    OUTPUT
    Continuous output power 4.0KW 6KW 8KW 10KW 12KW
    Surge rating (20ms) 12.0KW 15.0KW 18.0KW 24.0KW 30.0KW
    Capable Of Starting Electric Motor 2HP 3HP 3HP 4HP 5HP
    Output waveform Pure sine wave/ same as input (bypass mode)
    Inverter Efficiency(Peak) >88%
    Line mode efficiency >95%
    Power factor 0.8
    Nominal output voltage RMS 220V/230V/240VAC(±10% RMS)
    Output frequency 5OHz/60Hz±0.3 Hz
    Short circuit protection Yes (1sec after fault)
    Typical transfer time 10ms(max)
    10ms(max)
    AC
    INPUT
    Voltage 230VAC
    Selectable Voltage Range 155~280VAC(For Personal Computers)
    Frequency Range 50Hz/60Hz (Auto sensing) 40~80Hz
    BATTERY Minimum start voltage 20.OVDC/21.0VDC for24VDC mode (40.OVDC/42.0VDC for 48VDC mode)
    Low battery alarm 21.0VDC±0.3V for 24VDC mode (42.OVDC±0.6V  for 48VDC mode)
    Low battery Cutoff 20.0VDC±0.3V for 24VDC mode (40.OVDC±0.6V  for 48VDC mode)
    High voltage alarm 32.0VDC±0.3V for 24VDC mode (64.OVDC±0.6V  for 48VDC mode)
    High battery voltage recover 31.0VDC±0.3V for 24VDC mode (62.OVDC±0.6V  for 48VDC mode)
    Idle consumption-search mode <25W when power saver on
    CHARGER Output voltage Depends on battery type
    Charger AC input breaker rating 30A 30A 30A 40A 50A
    Max charge power rating 1/3 Rating power
    Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
    Maximum Charge Current 65A 35A 65A 40A 65A 50A 70A 80/120A
    BTS Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
    BYPASS
    &
    PROTECTION
    Input voltage waveform Sine wave (grid or generator)
    Nominal voltage 220V/230V/240VAC
    Max input AC voltage 300VAC for 230VAC HV mode
    Nominal input frequency 50Hz or 60Hz
    Overload protection (SMPS load) Circuit breaker
    Output short circuit protection Circuit breaker
    Bypass breaker rating 40A 40A 40A 50A 63A
    Max bypass current 40Amp 80Amp
    Rated voltage 24VDC/48VDC
    PV open circuit voltage Operational max = 145VDC temperature corrected VOC
    SOLAR
    CHARGER
    Maximum PV Charge Current 60/120A 60A(120A Optional)
    DC Voltage 48V atuo work 48V
    Maximum PV Array Power 1600W 3200W 1600W 3200W 1600W 3200W 3200W(6400W for 120A Optional)
    MPPT Range @ Operating Voltage 32~145VDC for 24V mode,64~145V for 48V mode 64~145VDC
    Maximum PV Array Open Circuit Voltage 147VDC 147VDC
    Maximum Efficiency >98%
    Standby Power Consumption <2W
    MECHANICAL
    SPECIFICATIONS
    Mounting Wall mount
    Inverter dimensions (W*H*D) 488*415*200mm 588*415*200mm
    Inverter weight (solar chg) KG 38+2.5 48+2.5 49+2.5 60+2.5 66+2.5
    Shipping dimensions(W*H*D) 650*520*310mm 750*520*310mm
    Shipping weight (solar chg) KG 40+2.5 50+2.5 51+2.5 62+2.5 68+2.5
    OTHER Operation   Temperature  Range 0°C to 40°C
    Storage   Temperature  -15°C to 60°C
    Audible   Noise 60dB MAX
    Display LED+LCD
    Standard warranty 1 year
    Packaging & Shipping
    +
     Products Packing:

    PV3500

    Why Choose Us
    MUST Power Revenue Growth Increases Every Year
    +
    Frequently Asked Questions:

    Q1: How to choose a right inverter?

    A1:Tell us your demand, then our sales will recommend a suitable inverter to you.

     

    Q2: What's the different between inverter and solar inverter?

    A2:  Inverter is only accept AC input, but solar inverter not only accept AC input but also can connect with solar panel to accept PV input, it more save power.

     

    Q3: How about the delivery time?

    A3:  7 days for sample; 25 days for bulk order.

     

    Q4: What is the warranty of inverter?

    A4: 12 Months warranty on Must-Solar product.

     

    Q5: How to solve the technical problem?

    A5: 24 hours after-service consultancy just for you and to make your problem to solve easily.

     

    Q6: Does the inverter connect with solar system?

    A6:Yes.Because of the unique feature which combine invert,charge and AC auto-transfer switch into one complete system,made inverter not only connect with solar system,also could be used in& officer equipment,household items,power tools ans etc..

     

    Q7: What kind of certificate you have ?

    A7: Our company already achieve ISO, CCC, and for products, we have CE, SONCAP, SAA, UL, etc.

     

    Contact us today to determine if you can take advantage of state solar energy incentives!